Our Price: $79.99 Instant Savings: $34.99 $45.00 |
|
CoolMAX CT-470 470W Aluminum w/ Trilight LED fan Item#: ECT-470 |
 |
 |
|
 |
|
 |
Click the thumbnails below to enlarge |
|
|
Points Credit : 45 points Currently valued at $0.90
Features Trilight LED Fan on the back panel (Blue, Red, Green)
Triple ball-bearing fans design, long life, noiseless and fastest cooling
time. Fan speed control adjustable function. (Auto, Middle and Lower Speed)
Fan speed monitor function for new M/B. High quality gold-coated fan
guard & connectors Tube-tide design and tidy your wires. Over
voltage protection, short circuit protection on all output levels. +5V stand
by 3A, the largest current in the market. Fully support all Intel & AMD
series demand 1. SCOPE: This specification defines the performance and
characteristic for model of CT-470 P4 Power Supply. 2. DIMENSION: (DxWxH)
6.4"x5.9"x3.3" / 163x150x86(mm) 3. AC INPUT: 3-1. AC Input: 95~132 VAC
or 190~264 VAC select switch,88~264VAC w/active PFCversion(optional) 3-2.
Frequency: 47HZ to 63HZ 3-3. Input Current: 12A maximum (RMS) at 115VAC,
6A maximum (RMS) at 230VAC 3-4. Inrush Current: 35A maximum at 115VAC, 70A
maximum at 230VAC 4. DC OUTPUT: 4-1. DC Output: Voltage Min. Current
Max. Current Peak Current Ripple +3.3V 0.3A 26.0A 28.0A 50mVp-p max.
+5V 0.1A 47.0A 54.0A 50mVp-p max. +12V 0.0A 28.0A 32.0A 120mVp-p max.
-5V 0.0A 0.5A 0.8A 50mVp-p max. -12V 0.0A 0.8A 1.0A 120mVp-p max.
+5V SB 0.0A 2.0A 2.5A 50mVp-p max.
( + 5V and +3.3V combined output
235W ) ( + 5V and +3.3V and +12V combined output 450W ) (Peak Current is
limited to total duration of 60 seconds) 4-2. Output Regulation: + 3.3V
+/- 5% Max. + 5V +/- 5% Max. + 12V +/-5% Max.(Normal Condition) -5V
+/- 10% Max. -12V +/- 10% Max. + 5VSB +/- 5% Max.
4-3. Line
Regulation: +/- 1% maximum at full load 4-4. Overshoot And
Undershoot: The output voltage has no overshoot or undershoot during turn-on
or turn-off the power supply 4-5. Overload And Short Protection: All DC
outputs are protected from overload circuit and short circuit condition 4-6.
Overvoltage protection: All DC outputs will be reduced to zero if the output
voltage threshold is exceeded. The overvoltage threshold of +5V output is
between 5.8V to 6.3V The overvoltage threshold of +12V output is between 14V
to 17V The overvoltage threshold of +3.3V output is between 3.6V to 4.2V
5. GENERAL SPECIFICATION: 5-1. Efficiency: 70% minimum at 115VAC , 470W
output 5-2. Operation Temperature: 0 ~ 50 degree C 5-3. Storage
temperature: -25 ~ 85 degree C 5-4. Humidity: Operating: 20% To 80% RH,
Storage: 10% To 90% RH 5-5. Hold Up Time: All output voltages will stay
within regulation for at least 16.6ms after an AC line voltage failure is
detected at nominal line (115 VAC or 230 VAC) under full load condition. 5-6.
Withstand Voltage: 2200VDC between input and ground for 1 minute Power
-down Warming Both +5V output voltage and AC input voltage are sense and
logical signal.The power good signal is pulled to TTL compatible high level for
normal operation and low level for faulty condition. The AC fail signal will
cause the power good signal going to a low level in 1 millisecond advance the DC
output fall below the regulation limits. The operating point is used as a
reference for measuring the1 millisecond as normal operation between minimum and
maximum loading.
|
 |
|
This product was added to our catalog on Wednesday November 02, 2005. |
|
 |